How does a solar backup generator work?
Looking for a solar backup generator for your photovoltaic system? The HISPANUS NERON ATS SOL and GETA ATS SOL models provide power when the inverter requests battery backup. Thanks to the dry contact signal from a compatible inverter, the system allows for automated generator start and stop.
Compare the two options, 3,600 W continuous for NERON and 7,500 W nominal for GETA, and choose according to the power requirements of your home, business, or off-grid installation. Technical support is available to check compatibility before you buy.
Comparison of solar backup generators
| Feature | NERON ATS SOL 4000W | GETA ATS SOL 8000W |
|---|---|---|
| Maximum power | 3,800 W | 8,000 W |
| Continuous/Nominal Power | 3,600 W | 7,500 W |
| Technology | Inverter | Inverter |
| System | ATS SOL via compatible inverter dry contact | |
| For guidance only | Moderate consumption | Increased demand and simultaneous consumption |
| Dimensions (width × depth × height) | 500 × 435 × 500 mm | 620 × 510 × 550 mm |
| Net weight | 38 kg | 74 kg |
| Tank capacity | 15 L | 25 L |
| Fuel | Gasoline | Gasoline |
| Starter type | Manual / Electric / Automatic ATS SOL | Manual / Electric / Automatic ATS SOL |
| Consumption / autonomy | 15 hours of autonomy at 50% charge | 0.5 L/h at 50% load (according to data sheet) |
| Oil: capacity and type | 0.6 L · SAE 5W30 | Consult the model manual |
| Power outlets | 2 × 16 A (Schuko) | 1 × 16 A + 1 × 32 A |
| Sound level | 60–70 dB at 7 m | <70 dB at 7 m |
| Output voltage | 230 V / 50 Hz | 230 V / 50 Hz |
| Product sheet | See NERON ATS SOL | See GETA ATS SOL |
How to choose an ATS SOL solar backup generator
A solar backup generator is used to supplement a photovoltaic system with batteries. It does not replace the solar panels; it provides an additional power source when solar production or available load is insufficient. The inverter or its control system must have a compatible start output; in some cases, a relay or a specific system adaptation is required.
The NERON ATS SOL 4000W, with 3,600 W continuous power, is suitable for installations with moderate demand. The GETA ATS SOL 8000W, with 7,500 W nominal power, is designed for higher consumption levels or multiple devices operating simultaneously. Before making a decision, check the actual power consumption of your appliances, the inverter's load capacity, and their startup current peaks.
The ATS SOL system responds to a control signal from the inverter; it should not be confused with an ATS generator designed for mains power outages. Connection, inverter adjustment, and flue gas venting must be carried out according to the manual and by qualified professionals. If you need help choosing, consult the product data sheets or request technical advice from HISPANUS.
Frequently asked questions about solar backup generators
How does a solar backup generator work?
When the inverter detects that the batteries require power, it sends a dry contact signal to the SOL ATS. The generator supplies power through the installation, and the inverter manages the load.
Is it compatible with Victron, Deye, Growatt, and other brands?
Yes, it is compatible with Victron, Deye, Growatt, and other brands of inverters. In some cases, it is advisable to install an external relay to protect the inverter's voltage-free contact and prevent potential damage. If your inverter does not have a voltage-free contact, we can offer a solution to add one, after verifying the model and the installation.
What is the difference between Nero and Geta?
Power: NERON has a maximum of 3,800 W and a continuous of 3,600 W; GETA has a maximum of 8,000 W and a nominal of 7,500 W, according to their specifications.
Do I need an installer?
The electrical connection and configuration of the inverter must be carried out by qualified professionals.
How do you recharge the batteries?
Through the inverter/charger, adjusting the demand so as not to exceed the available continuous power.